# GT Molecular > Ground Truth in Molecular Diagnostics ## Posts - [EV-D68](https://www.gtmolecular.com/ev-d68/): Enterovirus-68: Why is it a Public Health Risk? [cite: 1] By Layla Katiraee, GT Molecular [cite: 1] Enterovirus D68 (EV-D68) is a respiratory virus that has gained increasing attention from public health experts due to its potential to cause severe illness, especially in at-risk children[cite: 2]. As outbreaks continue to emerge, wastewater-based epidemiology (WBE) is proving to be a powerful tool for early detection and public health response[cite: 3]. What Is Enterovirus D68? [cite: 4] EV-D68 is a non-polio enterovirus that often leads to mild symptoms such as a runny nose, sneezing, and coughing[cite: 5]. However, children—particularly those with asthma […] - [HepA](https://www.gtmolecular.com/hepa/) - [HRS](https://www.gtmolecular.com/hrs/) - [Flu A/B](https://www.gtmolecular.com/flu-a-b/) - [Noro-adeno](https://www.gtmolecular.com/noro-adeno/) - [RSV](https://www.gtmolecular.com/rsv/) - [Arbovirus Panel](https://www.gtmolecular.com/arbovirus-panel/) ## Pages - [Flu A Sequencing Service for Wastewater](https://www.gtmolecular.com/wastewater-testing/flu-a-sequencing-service-for-wastewater/) - [Food & Beverage Testing](https://www.gtmolecular.com/food-and-beverage-testing/) - [SARS-CoV-2 Next-Generation Sequencing](https://www.gtmolecular.com/wastewater-testing/sars-cov-2-next-generation-sequencing/) - [Vector Copy Number Determination](https://www.gtmolecular.com/cancer-research-panels/vector-copy-number-determination/) - [Applied Biosystems™ QuantStudio™ Absolute Q™ Digital PCR System](https://www.gtmolecular.com/shop/applied-biosystems-quantstudio-absolute-q-digital-pcr-system/) - [Arbovirus Testing](https://www.gtmolecular.com/arbovirus-testing/) - [Microbially Influenced Corrosion](https://www.gtmolecular.com/microbial-influenced-corrosion/) - [PFAS Testing](https://www.gtmolecular.com/wastewater-testing/pfas-testing/) - [Microbial Source Tracking](https://www.gtmolecular.com/microbial-source-tracking/) - [Roche Digital LightCycler® System Assay Kits](https://www.gtmolecular.com/shop/roche-digital-lightcycler-system-assay-kits/) - [GT-Plex™ BCR-ABL Fusion Panel](https://www.gtmolecular.com/cancer-research-panels/gt-plex-bcr-abl-fusion-panel/) - [GT-Digital NPM1-W288fs*12 Insertion Detection Assay](https://www.gtmolecular.com/cancer-research-panels/gt-digital-npm1-w288fs12-insertion-detection-assay/) - [GT-Digital IDH1/IDH2/NPM1 Mutation Panel](https://www.gtmolecular.com/cancer-research-panels/gt-digital-idh1-idh2-npm1-mutation-panel/) - [GT-Plex™ ESR1 Panel](https://www.gtmolecular.com/cancer-research-panels/gt-plex-esr1-panel/) - [Microbial Community Analysis](https://www.gtmolecular.com/wastewater-testing/microbial-community-analysis/) - [Sample Intake form - general](https://www.gtmolecular.com/forms/): Sample upload * Forgot password Create Account Log in Sign up Reset password Intake Form: COVID-19 testing in municipal wastewater * Required GTID – Barcode number (located on form and sample tubes) *: Customer’s identifier written on tube (if available) : Name of the location where sample is taken *: Address of the location where sample is taken : Account Name *: Site time zone *: ChoosePacificMountainCentralEasternAlaskaHawaii Population served by site : Sampling method *: Flow-proportional 24-hr composite Volume-proportional 24-hr composite Time-proportional 24-hr composite Grab sample Other Auto-Sampler Section Start Date and time of Auto-Sampler sample collection *: End Date […] - [Terms & Conditions](https://www.gtmolecular.com/termsconditions/) - [Privacy policy](https://www.gtmolecular.com/privacy-policy/) - [Mpox](https://www.gtmolecular.com/mpox/) - [H5N1](https://www.gtmolecular.com/h5n1/) - [Custom Mass Spectrometry Assays](https://www.gtmolecular.com/custom-mass-spectrometry-assays/) - [Custom NGS Assays](https://www.gtmolecular.com/custom-ngs-assays/) - [Foundational & Translational Research](https://www.gtmolecular.com/foundational-and-translational-research-testing/) - [Cannabis Testing](https://www.gtmolecular.com/cannabis-microbial-testing-solutions/) - [Respiratory Pathogens](https://www.gtmolecular.com/infectious-disease-research-products/respiratory-pathogens/) - [Infectious Disease and Pathogen Detection](https://www.gtmolecular.com/infectious-disease-research-products/) - [GT-Plex™ KRAS Panels](https://www.gtmolecular.com/cancer-research-panels/gt-plex-kraspanels/) - [GT-Plex™ EGFR Panels](https://www.gtmolecular.com/cancer-research-panels/gt-plex-egfrpanels/) - [Cancer Research - PCR Panels](https://www.gtmolecular.com/cancer-research-panels/) - [Wastewater Respiratory Panel PCR Kits](https://www.gtmolecular.com/wastewater-and-water-pathogen-pcr-detection-kits/wastewater-respiratory-panel-pcr-kits/) - [Water & Wastewater Assay Kits](https://www.gtmolecular.com/wastewater-and-water-pathogen-pcr-detection-kits/) - [Applications for Oncology and Pathogen Detection](https://www.gtmolecular.com/applications/) - [Wastewater Drug Surveillance Services](https://www.gtmolecular.com/wastewater-testing/wastewater-drug-surveillance-services/) - [Next-Generation Sequencing Services](https://www.gtmolecular.com/wastewater-testing/next-generation-sequencing-services/) - [Pathogen and Microbial Testing Services](https://www.gtmolecular.com/wastewater-testing/pathogen-and-microbial-testing-services/) - [Webinars & Upcoming Events](https://www.gtmolecular.com/webinars-upcoming-events/) - [Contact](https://www.gtmolecular.com/contact/) - [Careers](https://www.gtmolecular.com/careers/) - [Press Releases](https://www.gtmolecular.com/news/) - [About Us](https://www.gtmolecular.com/about-us/) - [Dashboard](https://www.gtmolecular.com/dashboard/) - [Custom dPCR and qPCR Assays and Standards](https://www.gtmolecular.com/custom-dpcr-and-qpcr-assays-and-standards/) - [Product and services](https://www.gtmolecular.com/product-and-services/) - [Water & Wastewater Testing](https://www.gtmolecular.com/wastewater-testing/) - [My account](https://www.gtmolecular.com/my-account/) - [Checkout](https://www.gtmolecular.com/checkout/) - [Cart](https://www.gtmolecular.com/cart/) - [Shop](https://www.gtmolecular.com/shop/) - [Home](https://www.gtmolecular.com/) ## Products - [GT-Digital Microbial Source Tracking Human;E. coli; Cow; Pig; Dog; Sketa Panel v1.0 for the Bio-Rad QX600™ Droplet Digital™ PCR System](https://www.gtmolecular.com/product/gt-digital-microbial-source-tracking-human-ecoli-cow-pig-dog-sketa-assay-kit-v1-0-for-the-bio-rad-qx600-droplet-digital-pcr-system/): GT-Digital Microbial Source Tracking (MST) Human;E. coli;Cow;Pig;Dog;Sketa Panel v1.0 for the Bio-Rad QX600™ Droplet Digital™ PCR System is a molecular reagent kit consisting of all primers, probes, and controls necessary for detection of microbial DNA specific to human, cow, pig and dog Bacteroides species, as well as E. coli species. This assay also utilizes Sketa (Sketa-22, Salmon Sperm DNA) as a matrix recovery control (also called an internal process control), allowing the user to normalize extraction processes for potential differences in DNA recovery. - [GT-Digital Microbial Source Tracking Enterococcus;Sketa Assay Kit v1.0 for the Bio-Rad QX200™ or QX600™ Droplet Digital™ PCR System](https://www.gtmolecular.com/product/gt-digital-microbial-source-tracking-enterococcus-sketa-assay-v1-0-for-the-bio-rad-qx200-or-qx600-droplet-digital-pcr-system-copy/): The GT-Digital™ Microbial Source Tracking (MST) Enterococcus; Sketa Assay Assay v1.0 for the Bio-Rad QX200™ or QX600™ is a molecular reagent kit containing all primers, probes, and controls necessary for the wastewater surveillance of microbial DNA specific to Enterococcus from environmental water. - [Flu A Sequencing Service Add-on for Wastewater](https://www.gtmolecular.com/product/flu-a-sequencing-service-add-on-for-wastewater/): (Cat# 200269) This testing service covers Influenza A NGS testing that includes sequencing preparation, NGS H1 H3 Flu A Sequencing for segments H and N, data analysis, and consolidated report. ​ This add-on testing can be applied to any sample received by our laboratory that has already been quantified using our digital PCR (dPCR) testing service for the presence of Influenza A. This stands as a quality check to ensure sequencing is not performed and charges are not billed for a sample that does not contain influenza A. This offering can be packaged together as an add-on to our dPCR testing service (Cat# […] - [GT-Digital™ ESR1 Mutation Panel for the Applied BioSystems™ QuantStudio™ Absolute Q™ Digital PCR System](https://www.gtmolecular.com/product/gt-digital-esr1-mutation-detection-assay-kit-for-the-applied-biosystems-quantstudio-absolute-q-digital-pcr-system/): The GT-Digital ESR1 Mutation Panel for the Absolute Q™ Digital PCR System is a Research-Use Only (RUO), patent-pending molecular reagent kit containing all primers, probes, and controls for the detection and quantification of common mutations found in the human ESR1 gene. - [GT-Digital™ HepA Wastewater Surveillance Assay v1.0 for the QIAcuity® Digital PCR System – 200 Reactions](https://www.gtmolecular.com/product/gt-digital-hepa-wastewater-surveillance-assay-for-the-qiacuity/): (Cat# 101085) The GT-Digital™ HepA Wastewater Surveillance Assay v1.0 for the QIAGEN® QIAcuity® Digital PCR System comprises a molecular reagent kit containing all primers, probes, and controls required for the wastewater surveillance and quantification of hepatitis A (HepA). The use of these kits in conjunction with the QIAGEN® QIAcuity® instrument allows users to monitor HepA levels in wastewater. Validated for use with wastewater and while not validated for use with other kits, this assay uses the ROX channel, allowing for potential multiplexing with other GT Molecular Assay for the kits QIAGEN QIAcuity® instrument where this channel available.*DISCLAIMER! This assay does […] - [GT-Digital MeV WT M Gene Wastewater Surveillance Assay v1.0 for the QIAcuity® Digital PCR System – 200 Reactions](https://www.gtmolecular.com/product/gt-digital-mev-wt-m-gene-wastewater-surveillance-assay-v1-0-for-the-qiagen-qiacuity-digital-pcr-system/): (Cat# 101035) The GT-Digital MeV WT M Gene Wastewater Surveillance Assay v1.0 for the QIAcuity® Digital PCR System comprises a molecular reagent kit containing all primers, probes, and controls for wastewater surveillance of wild-type (WT) measles virus (MeV). Assay solutions and appropriate controls are provided for the quantification of measles virus. The two controls provided can be used to differentiate samples between the D8 and B3 genotype. The MeV WT M Gene Assay Solution v1.0 for the QIAcuity® can detect B3 and D8 genotypes. MeV WT M Gene Positive Control 1 and Control 2 serve as positive controls for B3 […] - [GT-Digital™ EV-D68 Wastewater Surveillance Panel v1.0 for the QIAcuity® Digital PCR System](https://www.gtmolecular.com/product/gt-digital-ev-d68-for-the-qiacuity-digital-pcr-system/): The GT-Digital™ EV-D68 Wastewater Surveillance Assay v1.0 for the QIAGEN® QIAcuity® Digital PCR System comprises a molecular reagent kit containing all primers, probes, and controls required for the wastewater surveillance and quantification of Enterovirus D68 (EV-D68). The use of these kits in conjunction with the QIAGEN® QIAcuity® instrument allows users to monitor EV-D68 levels in wastewater. Contains enough material for 200 reactions. - [GT-Digital Chikungunya Surveillance Assay v1.0 for the QIAGEN QIAcuity ® Digital PCR System](https://www.gtmolecular.com/product/gt-digital-chikv-arbovirus-surveillance-qiagen-qiacuity/): The GT-Digital Chikungunya Surveillance Assay v1.0 for the QIAGEN QIAcuity® Digital PCR System comprises a molecular reagent kit containing all primers, probes, and controls required for the surveillance and quantification of Chikungunya virus. This assay can be used as an optional add-on to allow for surveillance and quantification of Chikungunya virus (CHIKV) multiplexed with the (Cat# 101075) GT-Digital Arbovirus Surveillance Panel v1.0 for the surveillance and quantification of West Nile virus (WNV), dengue virus (DENV), and Zika virus (ZIKV). - [GT-Digital™ WNV;DENV;ZIKV Arbovirus Surveillance Assay v1.0 for the QIAGEN QIAcuity® Digital PCR System](https://www.gtmolecular.com/product/gt-digital-wnv-denv-zikv-arbovirus-surveillance-assay-for-the-qiagen-qiacuity-digital-pcr-system/): The GT-Digital Arbovirus Surveillance Panel v1.0 for the QIAGEN QIAcuity® Digital PCR System comprises a molecular reagent kit containing all primers, probes, and controls required for the surveillance and quantification of West Nile virus (WNV), dengue virus (DENV), and Zika virus (ZIKV). The GT-Digital Chikungunya Surveillance Assay kit v1.0 can be used as an optional add-on to allow for surveillance and quantification of Chikungunya virus (CHIKV). - [GT-Digital Human Papillomavirus (HPV) Assay Panel v1.0 for the Bio-Rad QX600™ Droplet Digital™ PCR System](https://www.gtmolecular.com/product/gt-digital-human-papillomavirus-hpv-assay-panel-v1-0-for-the-bio-rad-qx600-droplet-digital-pcr-system/): (Cat# 101070) GT-Digital Human Papillomavirus (HPV) Assay Panel v1.0 for the Bio-Rad QX600™ Droplet Digital™ PCR System is a molecular reagent kit consisting of all primers, probes, and controls necessary for detection of high-risk HPV viral DNA subtypes, including HPV 16 (FAM), HPV 18 (ROX), HPV 45 (HEX) and HPV 31 (Cy5). - [GT Molecular Merchandise](https://www.gtmolecular.com/product/gt-molecular-merchandise/): At GT Molecular, we believe science should spark conversations, not just happen quietly in the lab. By turning complex testing solutions into something fun and approachable, we help people connect the dots between the science and public health. Our swag is more than just t-shirts and stickers — it’s a way to celebrate the superheroes of science, share a laugh, and remind communities that protecting health can be both impactful and memorable. Because when people smile at funny shirts like a rainbow unicorn poop, they’re also learning that wastewater science is a powerful tool for tracking outbreaks, protecting families, and keeping communities safe. And that’s something worth wearing proudly. - [GT Real-Time qPCR Microbially Influenced Corrosion Panel v1.0 for the Bio-Rad™ CFX Opus 96 Real-Time PCR System](https://www.gtmolecular.com/product/microbially-influenced-corrosion-panel-for-the-bio-rad-cfx-opus-96-real-time-pcr-system/): The GT Real-Time qPCR Microbially Influenced Corrosion Panel v1.0 for the Bio-Rad CFX Opus Real-Time PCR Detection System is a molecular reagent kit containing primers, probes, and controls for the detection of sulfate reducing prokaryotes (SRP), highly corrosive methanogens (micH), sulfur oxidizing bacteria (SOB), Acetic Acid Producing Bacteria (AAPB), and total prokaryotes (TPK). Through the use of this kit in conjunction with the Bio-Rad™ CFX Opus instrument, users can quantify and monitor microbes associated with microbially influenced corrosion. - [GT-EZ Extraction Kit v1.0](https://www.gtmolecular.com/product/gt-ez-extraction-kit/): (Cat# 100675) The GT-EZ Extraction Kit v1.0 comprises a Research Use Only (RUO) reagent kit containing all reagents necessary for the extraction of bacterial DNA from a total of 96 samples. Perform a simple 15-minute extraction with the new GT-EZ Kit – faster AND easier than many standard protocols! Validated for use with GT Molecular assay kits such as The (Cat# 100640) GT Real-Time Salmonella and STEC Detection Assay Kit. - [GT Real-Time Salmonella & STEC Detection Assay Kit for Food & Beverage Testing – Bio-Rad CFX96™](https://www.gtmolecular.com/product/gt-real-time-salmonella-stec-detection-assay-kit-for-food-beverage-testing-bio-rad-cfx96/): (Cat# 100640-2.0) – For a package kit that includes master mix and extraction kit, contact us. This assay kit provides users with an end-to-end workflow to detect pathogenic Salmonella and Shiga toxin-producing E. coli (STEC) species from various food products. The GT-EZ Extraction Kit v1.0 (sold separately, contact us for packaged kit options) comprises a Research Use Only (RUO) reagent kit containing all reagents necessary for the extraction of bacterial DNA from food matrices. The GT Real-Time Salmonella and STEC Detection Assay Kit v2.0 comprises a RUO molecular reagent kit containing all primers, probes, master mix, and controls necessary for […] - [GT-Fast Prep ARTIC SARS-CoV-2 Library Preparation Kit](https://www.gtmolecular.com/product/gt-fast-prep-artic-sars-cov-2-library-preparation-kit/): The GT-Fast Prep ARTIC SARS-CoV-2 Library Preparation Kit is a molecular reagent kit containing all primers and reagents for the amplification and downstream preparation of SARS-CoV-2 gRNA extracts from wastewater matrices. - [GT-Digital™ Vector Copy Number: WPRE Assay Kit v1.0 for the QIAGEN QIAcuity® Digital PCR System](https://www.gtmolecular.com/product/gt-digital-vector-copy-number-wpre-assay-kit-for-the-qiagen-qiacuity-digital-pcr-system/): (Cat# 101015) GT-Digital™ Vector Copy Number: WPRE Assay Kit v1.0 for the QIAGEN QIAcuity® Digital PCR System is a molecular reagent kit consisting of all primers, probes, and controls necessary for the detection and quantification of a common viral vector genetic element (WPRE), present in lentiviral, adeno-associated, and retroviral vectors. It also detects a housekeeping control gene. The assay targets the Woodchuck Hepatitis Virus Posttranscriptional Response Element (WPRE; FAM) and the housekeeping gene Polypyrimidine Tract Binding Protein 1 (PTBT; HEX). This assay is designed to quantify the number of integrated viral vector copies containing WPRE elements relative to the genomic […] - [HMPV Wastewater Testing Service](https://www.gtmolecular.com/product/hmpv-wastewater-testing-service/): Wastewater testing service offering from our National Wastewater Testing Laboratory that targets human metapneumovirus (HMPV) strains using digital PCR detection. Includes collection kit, Priority Overnight return shipping and comprehensive report. - [GT-Digital™ HMPV Wastewater Surveillance Assay v1.0 for the Bio-Rad QX200™ or QX600™ Droplet Digital™ PCR System](https://www.gtmolecular.com/product/gt-digital-hmpv-wastewater-surveillance-assay-v1-0-for-the-bio-rad-qx200-or-qx600-droplet-digital-pcr-system/): (Cat# 101020) The GT-Digital™ HMPV Wastewater Surveillance Assay v1.0 for the Bio-Rad QX200™ or QX600™ Droplet Digital™ PCR System is a molecular reagent kit consisting of all primers, probes, and controls necessary for wastewater surveillance of Human Metapneumovirus (HMPV). Assay solution and positive control is provided for the quantification of Human Metapneumovirus virus. Through the use of this kit in conjunction with the Bio-Rad QX200™ or QX600™ Droplet Digital™ PCR System, users can monitor levels of HMPV. - [GT-Digital™ IDH1/IDH2/NPM1 Mutation Detection Assay Kit for the Applied BioSystems™ QuantStudio™ Absolute Q™ Digital PCR System](https://www.gtmolecular.com/product/gt-digital-idh1-idh2-npm1-mutation-detection-assay-kit-for-the-applied-biosystems-quantstudio-absolute-q-digital-pcr-system/): The GT-Digital™ IDH1/IDH2/NPM1 Mutation Detection Assay Kit for the QuantStudio™ Absolute Q™ Digital PCR System is a Research-Use Only (RUO), patent-pending molecular reagent kit containing all primers, probes, and controls for the detection and quantification of common mutations found in the human IDH1, IDH2, and NPM1 genes. This multi-target kit contains one assay solution and two qualitative controls. The assay solution contains a TAMRA probe that targets wild-type sequence at IDH1-R132 and Cy5 probes that target IDH1-R132C, IDH1-R132H, IDH2-R140Q, and IDH2-R172K mutations. The assay solution additionally contains a FAM probe which targets wild-type sequence at NPM1-W288 where common insertions occur and a HEX probe targeting wild-type sequence within the same amplicon. The presence of a short nucleotide insertion in the region of the FAM binding sequence results in a HEX-only positive signal (from the absence of FAM signal), whereas the presence of non-mutated NPM1 results in a FAM+HEX double positive signal. The assay was validated for the detection of the Type A NPM1 insertion (c.863insTCTG) and may also detect, but not discriminate between, Type B (c.863insCATG), D (c.863insCCTG), and other insertions occurring between c.863 and c.866. Rare NPM1 insertion types occurring between c.867 to c.875 may also be detected with the assay, resulting in a FAM-only positive signal (from the loss of HEX signal). However, these insertion types have not been tested. Qualitative controls included in the kit contain a mutated control at 10% variant allele frequency (VAF) and a wild-type control at 0% VAF for all target regions. . - [GT-Digital™ KRAS G12-G13 Mutation Detection Assay Kit for the Applied Biosystems™ QuantStudio™ Absolute Q™ Digital PCR System](https://www.gtmolecular.com/product/gt-digital-kras-g12-g13-mutation-panel-applied-biosystems-qauntstudio-absolute-q-dpcr/): The GT-Digital™ KRAS G12-G13 Mutation Detection Assay Kit for the QuantStudio™ Absolute Q™ Digital PCR System is a Research-Use Only (RUO), patent-pending molecular reagent kit containing all primers, probes, and controls for the detection and quantification of common mutations found in the human KRAS gene. This multi-target kit contains one assay solution and two qualitative controls. The assay solution targets the KRAS G12C, G12V, and G12A mutations in FAM; the G12S, G12R, and G13C mutations in HEX; the G12D and G13D mutations in Cy5; and wild-type KRAS G12-G13 in ABY. A 10% mixed mutant (MT) control and wild-type (WT) qualitative control are included in the kit. Contains enough material for 50 reactions. - [GT-Digital™ Soil-Transmitted Helminths Wastewater Surveillance Panel v1.0 for the Bio-Rad QX600™ Droplet Digital™ PCR System](https://www.gtmolecular.com/product/gt-digital-soil-transmitted-helminths-wastewater-panel-bio-rad-qx600/): (Cat# 100965) GT-Digital™ Soil-Transmitted Helminths (STH) Wastewater Surveillance Panel v1.0 for the Bio-Rad QX600™ Droplet Digital™ PCR System is a molecular reagent kit consisting of all primers, probes, and controls necessary for the detection of STH DNA, specific to Necator americanus, Ancylostoma duodenale, Ascaris lumbricoides, Trichuris trichiura, Strongyloides stercoralis species. This panel allows identification of STH contamination sources in wastewater (WW). The target used to detect Necator americanus (NecA) and Ancylostoma duodenale (AnsD) are located on ITS-2, the target for Trichuris trichiura (TriT) is located on ITS-1, for Strongyloides stercoralis the target (StrS) is on the 18S rRNA, and for […] - [GT-Quick qPCR Master Mix](https://www.gtmolecular.com/product/gtm-quick-qpcr-master-mix/): (Cat# 100769) A ready-to-use reaction mix for Real-Time PCR. This highly sensitive master mix is optimized for use with the GT Real-Time BCR-ABL Fusion Detection Panel Assay Kit. Contains enough material for 200 reactions. - [GT Real-Time BCR-ABL Fusion Detection Panel Assay Kit for QuantStudio™ 5 - BETA](https://www.gtmolecular.com/product/gt-real-time-bcr-abl-fusion-detection-panel-assay-kit/): (Cat# 100950) The GT Real-Time BCR-ABL Fusion Detection Panel Assay Kit is a Research-Use Only (RUO), patent-pending molecular reagent PCR kit containing all primers, probes, and controls necessary for the detection of human RNA with BCR-ABL translocations (Major (e13a2, e13a3, e14a2, e14a3), Minor (e1a2, e1a3), Micro (e19a2, e19a3), and Nano (e6a2, e6a3)). This multi-target kit contains one assay solution, one ABL1 positive control, and a positive control for each fusion type (e14a2, e1a2, e19a2, and e6a2). Users can determine the presence of these fusions in RNA extracted from blood or bone marrow samples on the QuantStudio™ 5™ Real-Time PCR system. […] - [Hepatitis A Wastewater Testing Service](https://www.gtmolecular.com/product/hepatitis-a-wastewater-testing-service/): (Cat# 100932) Fee-for-service Wastewater Test targets Hepatitis A strains using digital PCR detection. Includes collection kit and Priority Overnight return shipping. - [GT-Digital™ Microbially Influenced Corrosion Panel v1.0 for the QIAcuity® digital PCR System](https://www.gtmolecular.com/product/gt-digital-microbial-influenced-corrosion-panel-v1-0-for-the-qiacuity/): (Cat# 100850) The GT-Digital™ Microbially Influenced Corrosion Panel v1.0 for the QIAcuity® Digital PCR System is a molecular reagent kit containing primers, probes, and controls for the detection of key microbial organisms involved in microbially influenced corrosion (MIC). The enclosed panel targets sulfate reducing prokaryotes (SRP), highly corrosive methanogens (micH), sulfur oxidizing bacteria (SOB), Acetic Acid Producing Bacteria (AAPB), and total prokaryotes (TPK). Through the use of this kit in conjunction with the QIAcuity® instrument, users can quantify and monitor microbes associated with microbially influenced corrosion. Contains enough material for 100 reactions. - [GT-Digital™ MeV WT Cy5 Wastewater Surveillance Assay v1.0 for the QIAGEN QIAcuity® digital PCR System](https://www.gtmolecular.com/product/gt-digital-mev-wt-cy5-wastewater-surveillance-assay-v1-0-for-the-qiagen-qiacuity-digital-pcr-system/): (Cat# 100831) The GT-Digital™ MeV WT Cy5 Wastewater Surveillance Assay v1.0 for the QIAGEN QIAcuity® Digital PCR System comprises a molecular reagent kit containing all primers, probes, and controls required for the wastewater surveillance and quantification of wild-type Measles Virus (MeV). This kit provides an add-on to the GT-Digital™ NVO; Mpox Assay Kit for the QIAGEN QIAcuity® Digital PCR System (Cat#100459) and the GT-Digital™ HIV Wastewater Surveillance Assay (Cat#100870) used for the detection and quantification of NVO, mpox clade II, HIV-1, and HIV-2, respectively. The use of these kits in conjunction with the QIAGEN QIAcuity® instrument allows users to monitor […] - [GT-Digital H5* Wastewater Surveillance Assay v1.0 for the QIAcuity®](https://www.gtmolecular.com/product/gt-digital-h5-wastewater-surveillance-assay-v1-0-for-the-qiacuity/): (Cat# 100775) The GT-Digital H5* Wastewater Surveillance Assay Kit for the QIAcuity® Digital PCR System is an alpha released kit containing all primers, probes, and controls for wastewater surveillance of H5* influenza. Assay solutions and appropriate controls are provided for the detection and quantification of H5* influenza. Through the use of this kit in conjunction with the QIAGEN QIAcuity® instrument, users can monitor H5* influenza levels. Contains enough material for 200 reactions. - [Norovirus GI;GII Wastewater Testing Service](https://www.gtmolecular.com/product/norovirus-gi-gii-testing-service/): (Cat# 100764) Wastewater Testing Service capable of detecting Norovirus GI;GII in wastewater. Includes collection kit and Priority Overnight return shipping. - [GT-Digital™ Noro;Adeno Wastewater Surveillance Panel for the Bio-Rad QX600™](https://www.gtmolecular.com/product/gt-digital-noroadeno-wastewater-surveillance-panel-for-the-qx600/): (Cat# 100755)  The GT-Digital™ Noro;Adeno Wastewater Surveillance Panel for the Bio-Rad QX600? Droplet Digital? PCR System comprises a molecular reagent kit containing assay solutions and appropriate controls for the detection and quantification of 1) norovirus GI; 2) norovirus GII; 3) adenovirus; and 4) bovine coronavirus (BCoV), a matrix recovery control/process control. Through the use of this kit in conjunction with the Bio-Rad QX600? Droplet Digital? PCR System, users can monitor norovirus and adenovirus levels at the community level and normalize for changes in viral recovery caused by the variable and complex nature of wastewater. Contains enough material for 200 reactions. - [SARS-CoV-2 Sequencing Service for RNA Sample](https://www.gtmolecular.com/product/sars-cov-2-sequencing-service-for-rna-sample/): (Cat# 100396) Full service NGS of extracted RNA sample includes, shipping, processing, sequencing, and report generation. Collection kits are nonreturnable and nonrefundable. - [GT-Digital™ Polio Typing Wastewater Surveillance Assay Kit for the QIAcuity®](https://www.gtmolecular.com/product/dpcr-polio-typing-wastewater-surveillance-assay-kit-for-the-qiacuity/): (Cat# 100340) The GT-Digital™ Polio Typing Wastewater Surveillance Assay Kit for the QIAcuity® Digital PCR System comprises a molecular reagent kit containing assay solutions and appropriate controls for the quantification and discrimination of 1) Poliovirus types (PV1, PV2 and PV3); 2) Simian virus 6 (SV6), a matrix recovery control (also called an internal process control) biologically similar to Poliovirus; and 3) Pepper Mild Mottle virus (PMMoV), a fecal indicator that can estimate the human fecal content in a sample. Through use of this kit in conjunction with the QIAGEN QIAcuity® instrument, users can monitor PV levels and normalize for changes […] - [GT-Digital™ Microbial Source Tracking Human;E.coli;Cow;Gull;Dog Panel v1.0 for the QIAGEN QIAcuity® Digital PCR System](https://www.gtmolecular.com/product/gt-digital-microbial-source-tracking-humane-colicowgulldog-panel-v1-0-for-the-qiagen-qiacuity-digital-pcr-system/): GT-Digital™ Microbial Source Tracking Human;E.coli;Cow;Gull;Dog Panel v1.0 for the QIAGEN QIAcuity® Digital PCR System is a molecular reagent kit consisting of all primers, probes, and controls necessary for detection of microbial DNA specific to human, cow, gull and dog Bacteroides species, as well as E. coli species. - [GT Quantitative Real-Time Flu;SC2;RSV;BCoV Wastewater Surveillance Assay v1.0](https://www.gtmolecular.com/product/gt-real-time-pcr-wastewater-sars-cov-2-flu-a-b-rsv-and-bcov-assay-kit/): The GT-Quantitative Real Time Flu;SC2;RSV;BCoV Wastewater Surveillance Assay v1.0 developed for the QuantStudio 5®, Bio-Rad CFX96™ or similar platform, is a molecular reagent kit consisting of all primers, probes, and controls necessary for wastewater surveillance of influenza (Flu), SARS-CoV-2 (SC2), and respiratory syncytial virus (RSV). Assay solutions and appropriate controls are provided for the quantification of 1) influenza A/B; 2) RSV A/B; 3) SARS-CoV-2; and 4) bovine coronavirus (BCoV), a matrix. - [GT-Digital™ Mpox Clade I OPG210 ROX Add-On Assay v1.0 for the Bio-Rad QX600™ Droplet Digital™ PCR System](https://www.gtmolecular.com/product/gt-digital-mpox-clade-i-opg210-rox-add-on-assay-v1-0-for-the-bio-rad-qx600-digital-pcr-system-copy/): The GT-Digital™ Mpox Clade I OPG210 ROX Add-On assay for the Bio-Rad QX600™ Droplet Digital™ PCR System is a molecular reagent kit consisting of all primers, probes, and controls necessary for wastewater surveillance of mpox clade I. - [GT-Digital™ Mpox Clade I OPG210 ROX Add-On Assay v1.0 for the QIAcuity® Digital PCR System](https://www.gtmolecular.com/product/gt-digital-mpox-clade-i-opg210-rox-add-on-assay-qiacuity/): The GT-Digital™ Mpox Clade I OPG210 ROX Add-On Assay for the QIAcuity® Digital PCR System comprises a molecular reagent kit containing all primers, probes, and controls for wastewater surveillance of Mpox Clade I. - [PFAS Testing Service: EPA Method 537 for Drinking Water Samples by LC-MS/MS (14 targets)](https://www.gtmolecular.com/product/pfas-testing-service-epa-method-537-for-drinking-water-samples-by-lc-ms-ms-14-targets/): Method 537 monitors 14 PFAS in drinking water using solid phase extraction and liquid chromatography/tandem mass spectrometry (LC/MS/MS). - [PFAS Testing Service: EPA Method 533 for Drinking Water Samples by LC-MS/MS (25 targets)](https://www.gtmolecular.com/product/pfas-testing-service-epa-method-533-for-drinking-water-samples-by-lc-ms-ms/): Method 533 monitors 25 PFAS in drinking water using isotope dilution anion exchange solid phase extraction (SPE) and liquid chromatography/tandem mass spectrometry (LC/MS/MS). - [PFAS Testing Service: EPA Method 1633A for Aqueous, Solid, Biosolids, and Tissue Samples by LC-MS/MS (40 targets)](https://www.gtmolecular.com/product/pfas-testing-services-epa-method-1633a/): Method 1633, Revision A: Analysis of Per- and Polyfluoroalkyl Substances (PFAS) in Aqueous, Solid, Biosolids, and Tissue Samples by LC-MS/MS - [GT-Digital™ HepA ROX Add-On Wastewater Surveillance Assay v1.0 for the Bio-Rad QX600™ Droplet Digital™ PCR System](https://www.gtmolecular.com/product/gt-digital-hepa-rox-add-on-wastewater-surveillance-assay-v1-0-for-the-bio-rad-qx600-droplet-digital-pcr-system/): The GT-Digital™ HepA ROX Add-On Wastewater Surveillance Assay v1.0 for the Bio-Rad QX600™ Droplet Digital™ PCR System is a molecular reagent kit consisting of all primers, probes, and controls necessary for wastewater surveillance of hepatitis A (HepA). - [GT-Digital™ Microbial Source Tracking Dog;Pig Assay v1.0 for the Bio-Rad QX200™ or QX600™ Droplet Digital™ PCR System](https://www.gtmolecular.com/product/gt-digital-microbial-source-tracking-dogpig-assay-v1-0-for-the-bio-rad-qx200-or-qx600-droplet-digital-pcr-system/): GT-Digital™ Microbial Source Tracking (MST) Dog;Pig Assay v1.0 for the Bio-Rad QX200™ or QX600™ Droplet Digital™ PCR System is a molecular reagent kit consisting of all primers, probes, and controls necessary for detection of microbial DNA specific to dog and pig Bacteroides species. - [GT-Digital™ Microbial Source Tracking Human;Cow Assay v1.0 for the Bio-Rad QX200™ or QX600™ Droplet Digital™ PCR System](https://www.gtmolecular.com/product/gt-digital-microbial-source-tracking-humancow-assay-v1-0-for-the-bio-rad-qx200-or-qx600-droplet-digital-pcr-system/): GT-Digital™ Microbial Source Tracking (MST) Human;Cow Assay v1.0 for the Bio-Rad QX200™ or QX600™ Droplet Digital™ PCR System is a molecular reagent kit consisting of all primers, probes, and controls necessary for detection of microbial DNA specific to human and cow Bacteroides species. - [GT-Digital™ Microbial Source Tracking E.coli;Sketa Assay v1.0 for the Bio-Rad QX200™ or QX600™ Droplet Digital™ PCR System](https://www.gtmolecular.com/product/gt-digital-microbial-source-tracking-ecoli-sketa-assay-for-the-qx200/): The GT-Digital™ Microbial Source Tracking (MST) E.coli;Sketa Assay v1.0 for the Bio-Rad QX200™ or QX600™ is a molecular reagent kit containing all primers, probes, and controls necessary for the wastewater surveillance of microbial DNA specific to E.coli from environmental water. - [GT-Digital™ West Nile Virus Wastewater Surveillance Assay v1.0 for the QIAGEN QIAcuity® Digital PCR System](https://www.gtmolecular.com/product/gt-digital-west-nile-virus-wastewater-surveillance-assay-v1-0-for-the-qiagen-qiacuity-digital-pcr-system/): The GT-Digital™ West Nile Virus Wastewater Surveillance Assay v1.0 for the QIAGEN QIAcuity® Digital PCR System comprises a molecular reagent kit containing all primers, probes, and controls required for the wastewater surveillance and quantification of West Nile virus (WNV). - [GT-Digital™ HIV Wastewater Surveillance Assay v1.0 for the QIAGEN QIAcuity® Digital PCR System](https://www.gtmolecular.com/product/gt-digital-hiv-wastewater-surveillance-assay-v1-0-for-the-qiagen-qiacuity-digital-pcr-system/): The GT-Digital™ TB Wastewater Surveillance Assay v1.0 for the QIAGEN QIAcuity® Digital PCR System comprises a molecular reagent kit containing all primers, probes, and controls required for the wastewater surveillance and quantification of the Mycobacterium tuberculosis Complex (MTBC), including Mycobacterium tuberculosis (Mtb). - [GT-Digital™ TB Wastewater Surveillance Assay v1.0 for the QIAGEN QIAcuity® Digital PCR System](https://www.gtmolecular.com/product/gt-digital-tb-wastewater-surveillance-assay-v1-0-for-the-qiagen-qiacuity-digital-pcr-system/): The GT-Digital™ TB Wastewater Surveillance Assay v1.0 for the QIAGEN QIAcuity® Digital PCR System comprises a molecular reagent kit containing all primers, probes, and controls required for the wastewater surveillance and quantification of the Mycobacterium tuberculosis Complex (MTBC), including Mycobacterium tuberculosis (Mtb). - [Influenza H5 Milk Testing (including H5N1 subtype)](https://www.gtmolecular.com/product/sars-cov-2-influenza-a-b-wastewater-testing-service-copy/): (Cat# 100859) Wastewater Testing Service capable of detecting H5N1 in milk. Includes collection kit and Priority Overnight return shipping. - [GT-Digital™ Flu;SC2;RSV;BCoV WW Surveillance Panel v1.0 for the QX600™](https://www.gtmolecular.com/product/gt-digital-flusc2rsvbcov-ww-surveillance-panel-v1-0-for-the-qx600/): (Cat# 100765) The GT-Digital™ Flu;SC2;RSV;BCoV Wastewater Surveillance Panel for the Bio-Rad QX600™ Droplet Digital™ PCR System comprises a molecular reagent kit containing all assay solutions and appropriate controls for the quantification of 1) Influenza A; 2) Influenza B; 3) SARS-CoV-2; 4) Respiratory Syncytial Virus (RSV); and 5) Bovine Coronavirus (BCoV), a matrix recovery control (also called an internal process control) biologically similar to RSV. Through use of this kit in conjunction with the Bio-Rad QX600™ Droplet Digital™ PCR system, users can monitor influenza virus, SARS-CoV-2 and RSV levels and normalize for changes in viral recovery as well as normalize for […] - [GT-Digital™ H5*;FluA Wastewater Surveillance Assay v1.0 for the QX200™/QX600™](https://www.gtmolecular.com/product/gt-digital-h5flua-wastewater-surveillance-assay-v1-0-for-the-qx200-qx600/): (Cat# 100700) A molecular reagent kit consisting of all primers, probes, and controls necessary for wastewater surveillance of H5* influenza and pan-influenza A. Assay solutions and appropriate controls are provided for the quantification of H5* influenza and pan-influenza A. Through the use of this kit in conjunction with the Bio-Rad QX200™ or QX600™ Droplet Digital™ PCR Systems, users can monitor H5* influenza and pan-influenza A levels. Contains enough material for 200 reactions. - [GT-Digital™ PMMoV Fecal Indicator Assay Kit for the QIAcuity®](https://www.gtmolecular.com/product/gt-digital-crassphage-fecal-indicator-assay-kit-for-the-qiacuity-copy/): The GT-Digital™ PMMoV Fecal Indicator Assay Kit for the QIAcuity® Digital PCR System is a molecular reagent kit containing an assay solution and appropriate control for the quantification of PMMoV, a fecal indicator used to quantify human fecal content in a sample. Through the use of this kit in conjunction with the QIAGEN QIAcuity® instrument, users can monitor PMMoV levels and normalize for human waste input. Contains enough material for 200 reactions. - [C. auris Wastewater Testing Service](https://www.gtmolecular.com/product/c-auris-wastewater-testing-service/): (Cat# 100374) Fee-for-service Wastewater Test detects targets specific to C. auris. Includes collection kit and Priority Overnight return shipping. - [GT-Digital™ crAssphage Fecal Indicator Assay Kit for the QIAcuity®](https://www.gtmolecular.com/product/gt-digital-crassphage-fecal-indicator-assay-kit-for-the-qiacuity/): (Cat#100350) The GT-Digital™ crAssphage Fecal Indicator Assay Kit for the QIAcuity® Digital PCR System is a molecular reagent kit containing an assay solution and appropriate control for the quantification of crAssphage, a fecal indicator used to quantify human fecal content in a sample. Through the use of this kit in conjunction with the QIAGEN QIAcuity® instrument, users can monitor crAssphage levels and normalize for human waste input. Contains enough material for 200 reactions. - [GT-Digital™ Flu;SC2;RSV;BCoV Wastewater Surveillance Panel v1.0 for the QIAcuity® Digital PCR System](https://www.gtmolecular.com/product/gt-digital-flusc2rsvbcov-wastewater-surveillance-panel-v1-0-for-the-qiacuity-digital-pcr-system/): (Cat# 100770) The GT-Digital™ Flu;SC2;RSV;BCoV Wastewater Surveillance Panel for the QIAcuity® Digital PCR System comprises a molecular reagent kit containing all primers, probes, and controls for wastewater surveillance of influenza (Flu) A/B, respiratory syncytial virus (RSV) A/B, and SARS-CoV-2 (SC2). Assay solutions and appropriate controls are provided for the quantification of 1) influenza A; 2) influenza B; 3) RSV A/B; 3) SARS-CoV-2; and 4) bovine coronavirus (BCoV), a matrix recovery control/process control. Through the use of this kit in conjunction with the QIAGEN QIAcuity® instrument, users can monitor influenza, RSV, and SARS-CoV-2 levels at the community level and normalize for […] - [GT-Digital™ HIV Wastewater Surveillance Assay v1.0 for the Bio-Rad QX200™ or QX600™ Droplet Digital™ PCR System](https://www.gtmolecular.com/product/2438/): Cat#100830 The GT-Digital™ HIV Wastewater Surveillance Assay v1.0 for the Bio-Rad QX200™ or QX600™ Droplet Digital™ PCR System is a Research-Use Only (RUO) molecular reagent kit consisting of all primers, probes, and controls necessary for the wastewater surveillance of human immunodeficiency virus (HIV). An assay solution and appropriate controls are provided for the detection, discrimination, and quantification of HIV-1 (FAM) and HIV-2 (HEX), two distinct types of HIV. Through the use of this kit in conjunction with the Bio-Rad QX200™ or QX600™ Droplet Digital™ PCR System, users can monitor HIV levels in wastewater. - [16S Sequencing of Wastewater for Microbial Community Analysis](https://www.gtmolecular.com/product/16s-sequencing-service-for-wastewater-sample/): (Cat# 200258) Full 16S NGS testing service for microbial community analysis with sample processing, sequencing, and report generation. Collection kit and Priority Overnight return shipping also included. Identification of Bacteria, Archaea, & Fungi from any Microbiome Sample – wastewater, environmental waters, gut, etc. Full 16S microbiome / metagenomics analysis and detailed species-level report Contact us for more details and example reporting! - [Measles Wastewater Testing Service](https://www.gtmolecular.com/product/measles-wastewater-testing-service/): Wastewater Testing Service: Targets Wild Type (WT) measles (MeV). Includes collection kit and Priority Overnight return shipping. - [GT-Digital™ MeV WT Wastewater Surveillance Assay v1.0 for the Bio-Rad QX200™ or QX600™ Droplet Digital™ PCR System](https://www.gtmolecular.com/product/gt-digital-mev-wt-wastewater-surveillance-assay-v1-0-for-the-bio-rad-qx200-or-qx600-droplet-digital-pcr-system/): (Cat# 100840) The GT-Digital™ MeV WT Wastewater Surveillance Assay v1.0 for the Bio-Rad QX200™ or QX600™ Droplet Digital™ PCR System is a molecular reagent kit consisting of all primers, probes, and controls necessary for wastewater surveillance of wild-type (WT) measles virus (MeV). Assay solutions and appropriate controls are provided for the quantification of wild-type measles virus. Through the use of this kit in conjunction with the Bio-Rad QX200™ or QX600™ Droplet Digital™ PCR System, users can monitor wild-type measles levels. *IMPORTANT! This assay was designed to ensure no detection of vaccine derived strains of measles virus. - [GT-Digital™ MeV WT Wastewater Surveillance Assay v1.0 for the QIAcuity® Digital PCR System](https://www.gtmolecular.com/product/gt-digital-mev-wt-wastewater-surveillance-assay-v1-0-for-the-qiacuity-digital-pcr-system/): (Cat# 100835) The GT-Digital™ MeV WT Wastewater Surveillance Assay v1.0 for the QIAcuity® Digital PCR System comprises a molecular reagent kit containing all primers, probes, and controls for wastewater surveillance of wild-type (WT) measles virus (MeV). Assay solutions and appropriate controls are provided for the quantification of wild-type measles virus. Through the use of this kit in conjunction with the QIAGEN QIAcuity® instrument, users can monitor wild-type measles levels. *IMPORTANT! This assay was designed to ensure no detection of vaccine derived strains of measles virus. - [GT Real-Time Aspergillus Detection Assay Kit: AriaMX Real-Time PCR System](https://www.gtmolecular.com/product/gt-real-time-aspergillus-detection-assay-kit-ariamx-real-time-pcr-system/): (Cat# 100800) Molecular assay for the detection of Aspergillus flavus, Aspergillus fumigatus, Aspergillus niger, and Aspergillus terreus from a cannabis matrix. The provided assay solution targets genomic loci on A. flavus, A. fumigatus, A. niger, A. terreus, and Cannabis. For use with the AriaMx or similar Real-Time PCR system. Contains enough material for 200 reactions. For Research Use Only. - [Opioid Testing Service for Wastewater Sample (6+ Targets)](https://www.gtmolecular.com/product/opioid-testing-service-for-wastewater-sample-6-targets/): Opioid panel (6+ targets) with report for wastewater sample. Contact us to learn more! - [Moore Swab Kit for Wastewater Testing Service](https://www.gtmolecular.com/product/moore-swab-kit-for-wastewater-testing-service/): (Cat# 200261) Moore Swab Kit for Wastewater Testing Service and Priority Overnight return shipping. - [Respiratory Panel Wastewater Test](https://www.gtmolecular.com/product/respiratory-panel-wastewater-test/): (Cat# 200259) Wastewater Testing Service: Targets Influenza A, Influenza B, RSV and SARS-CoV-2. Includes collection kit and Priority Overnight return shipping. - [SARS-CoV-2 Sequencing Service for Wastewater](https://www.gtmolecular.com/product/sars-cov-2-sequencing-service-for-wastewater-sample/): (Cat# 200255) Full service NGS includes wastewater sample collection kit, shipping, processing, sequencing, and report generation. - [GT-Digital™ NVO WW Surveillance Assay Kit v1.0 for the QIAcuity™-BETA](https://www.gtmolecular.com/product/gt-digital-nvo-ww-surveillance-assay-kit-v1-0-for-the-qiacuity-beta/): (Cat# 100821) The GT-Digital™ NVO Wastewater Surveillance Assay Kit v1.0 for the QIAcuity™  Digital PCR System comprises a molecular reagent kit containing all primers, probes, and controls for the detection of non-variola Orthopoxviruses (NVO) in wastewater. Through use of this kit in conjunction with the QIAGEN™  QIAcuity Digital PCR systems, users can monitor NVO levels in wastewater. Contains enough material for 200 reactions. - [Respiratory Panel Wastewater Test (qPCR)](https://www.gtmolecular.com/product/respiratory-panel-wastewater-test-qpcr/): (Cat# 100789) Wastewater Testing Service- targets Influenza A, Influenza B, RSV and SARS-CoV-2 using qPCR. Includes collection kit and Priority Overnight return shipping. - [SARS-CoV-2 Single Test (qPCR)](https://www.gtmolecular.com/product/sars-cov-2-single-test-qpcr/): (Cat# 100788) Wastewater Test ing Service- targets N1 region of SARS-CoV-2, the virus that causes COVID-19 using qPCR. Includes collection kit and Priority Overnight return shipping. - [GT-Digital™ Flu;SC2;RSV Wastewater Surveillance Panel v1.0 for the QuantStudio™ Absolute Q™ Digital PCR](https://www.gtmolecular.com/product/gt-digital-flusc2rsv-wastewater-surveillance-panel-for-the-absolute-q/): (Cat# 100785) The GT-Digital™ Flu;SC2;RSV Wastewater Surveillance Panel for the QuantStudio? Absolute Q™ Digital PCR System comprises a molecular reagent kit containing assay solutions and appropriate controls for the detection and quantification of 1) Influenza A; 2) Influenza B; 3) SARS-CoV-2; and 4) Respiratory Syncytial Virus (RSV). Through use of this kit in conjunction with the QuantStudio™ Absolute Q™ Digital PCR System, users can monitor influenza virus, SARS-CoV-2 and RSV levels. Contains enough material for 200 reactions. - [Influenza H5* Wastewater Test](https://www.gtmolecular.com/product/influenza-h5-wastewater-test/): (Cat# 100783) Wastewater Testing Service- targets Influenza H5* strains. Includes collection kit and Priority Overnight return shipping. Contact us for details. - [GT-Digital™ H5* Crimson Add-On WW Surveillance Assay v1.0 for the QIAcuity®](https://www.gtmolecular.com/product/gt-digital-h5-crimson-add-on-ww-surveillance-assay-v1-0-for-the-qiacuity/): (Cat# 100778) A molecular reagent kit consisting of an assay solution and control necessary for the quantification of H5* influenza. Through the use of this kit in conjunction with the QIAGEN QIAcuity® Digital PCR systems, users can monitor H5* influenza levels. Contains enough material for 200 reactions. - [GT-Digital™ Noro;Adeno Wastewater Surveillance Panel for the QIAcuity™](https://www.gtmolecular.com/product/gt-digital-noroadeno-wastewater-surveillance-panel-for-the-qiacuity/): (Cat# 100750) The GT-Digital™ Noro;Adeno Wastewater Surveillance Panel for the QIAcuity™ Digital PCR System comprises a molecular reagent kit containing assay solutions and appropriate controls for the detection and quantification of 1) norovirus GI; 2) norovirus GII; 3) adenovirus; and 4) bovine coronavirus (BCoV), a matrix recovery control/process control. Through the use of this kit in conjunction with the QIAGEN QIAcuity™ instrument, users can monitor norovirus and adenovirus levels at the community level and normalize for changes in viral recovery caused by the variable and complex nature of wastewater. Contains enough material for 200 reactions. - [Custom Software Solution](https://www.gtmolecular.com/product/custom-software-solution/): (Cat# 100748) Custom Sample Management System and Web Portal. Contact us to setup a system that works for your testing! - [GT-Digital™ KRAS G12-G13 Mutation Typing Kit v1.0 for the QIAcuity™](https://www.gtmolecular.com/product/gt-digital-kras-g12-g13-mutation-typing-kit-v1-0-for-the-qiacuity/): (Cat# 100720) The GT-Digital™ KRAS G12-G13 Mutation Typing Kit for the QIAcuity™ Digital PCR System is a Research-Use Only (RUO) molecular reagent kit containing all primers, probes, and controls for the detection and quantification of the following KRAS mutations: G12C, G12V, G12S, G12A, G12R, G12D, G13C, and G13D. This assay does not recognize other KRAS mutations. This kit comprises two 5-plex assay solutions targeting four different KRAS mutations paired with a corresponding wild-type target at the G12 and G13 codons. This kit includes mixed controls for each respective assay at 10% variant allele frequency (VAF) and two tubes of 100% […] - [WW Sample Collection Kit with Outbound and Return Shipping](https://www.gtmolecular.com/product/ww-sample-collection-kit-with-outbound-and-return-shipping/): (Cat# 100710) Kit contains all supplies necessary for wastewater sample collection, outbound shipping and priority overnight return shipping. - [GT-Digital™ Adenovirus WW Surveillance Assay Kit v1.0 for the QIAcuity™](https://www.gtmolecular.com/product/gt-digital-adenovirus-ww-surveillance-assay-kit-v1-0-for-the-qiacuity/): (Cat 100685) The GT-Digital™ Adenovirus Wastewater Surveillance Assay Kit for the QIAcuity™  comprises an assay solution and control required for the quantification of enteric adenovirus (Type 40/41). Through use of this kit in conjunction with the QIAcuity™ , users can monitor adenovirus levels in wastewater. This kit can also be used as an add-on to the GT-Digital™ Norovirus GI;Norovirus GII Assay Kit v1.1 for QIAcuity™  (Cat#100469-1.1). Contains enough material for 200 reactions. - [Starter Aspergillus + Salmonella & STEC (Assays, Controls, Mastermix & Extraction Solutions)](https://www.gtmolecular.com/product/starter-aspergillus-salmonella-stec-assays-controls-mastermix-extraction-solutions/): (Cat# 100677) Contact us for more details and to get your facility setup with a starter kit! - [GT Real-Time KRAS G12-G13 Typing PCR Kit](https://www.gtmolecular.com/product/gt-real-time-kras-g12-g13-typing-pcr-kit/): (Cat# 100615) The GT Real-Time KRAS G12-G13 Typing PCR Kit is a Research-Use Only (RUO) patent-pending molecular reagent kit containing all primers, probes, and controls necessary for the detection and discrimination of eight different mutations found within the G12 and G13 codon regions of the corresponding KRAS gene. The kit contains three separate assays for the detection of KRAS G12C, G12V, G12S, G12A, G12R, G12D, G13C, and G13D mutations. Each assay also includes a universal target that indicates total DNA containing the KRAS gene present. Users can determine the presence of these mutations from extracted FFPE and/or liquid biopsy samples […] - [GT-Digital™ PMMoV;CrAssphage Assay Kit v1.1 for the QIAcuity™ -BETA](https://www.gtmolecular.com/product/gt-digital-pmmovcrassphage-assay-kit-v1-1-for-the-qiacuity-beta/): (Cat# 100609-1.1) The GT-Digital™ PMMoV;crAssphage Assay Kit v1.1 for the QIAcuity™  comprises a molecular reagent kit containing all primers, probes, and controls for the detection of pepper mild mottle virus (PMMoV) and crAssphage fecal indicators in wastewater. Through use of this kit in conjunction with the QIAGEN QIAcuity™ , users can monitor PMMoV and crAssphage levels in wastewater. Contains enough material for 200 samples. - [Wastewater Inhibition Assessment](https://www.gtmolecular.com/product/wastewater-inhibition-assessment/): (Cat# 100397) Wastewater Testing Service- test assesses sample matrix inhibition of viral/target signature. Includes collection kit and Priority Overnight return shipping. - [SARS-CoV-2 + Influenza A/B Wastewater Testing Service](https://www.gtmolecular.com/product/sars-cov-2-influenza-a-b-wastewater-testing-service/): (Cat# 100380) Wastewater Testing Service detects targets specific to SARS-CoV-2 Single Test and Influenza A/B. Includes collection kit and Priority Overnight return shipping. - [Opioid Testing Service for Wastewater Sample (1-5 Targets)](https://www.gtmolecular.com/product/opioid-testing-service-for-wastewater-sample-1-5-targets/): Panel consists of 9 total analytes including five parent targets and five metabolites. Parent targets include methamphetamine, cocaine, fentanyl, naloxone, and nicotine. - [Wastewater Sampling Logistics: Sample Collection Kit Overnight Return Shipping](https://www.gtmolecular.com/product/ww-kit-logistics-sample-collection-kit-overnight-return-shipping/): Overnight express return shipping to laboratory facility. Simplify your testing. Let us handle the shipping service! - [Wastewater Sampling Logistics: Sample Collection Kit Outbound Shipping](https://www.gtmolecular.com/product/ww-kit-logistics-sample-collection-kit-outbound-shipping/): Shipping to wastewater collection facilities. Let us handle the shipping service so you don't have too! Contact us to see how we can make your collection, testing, and shipping easier. - [Wastewater Sampling Logistics: Sample Collection Kit](https://www.gtmolecular.com/product/ww-kit-logistics-sample-collection-kit/): Kit contains all supplies necessary for wastewater sample collection, tracking and transport. Contact us to see how we can make your collection, testing, and shipping easier. - [SARS-CoV-2 Single Test (Total N1) + Influenza A/B](https://www.gtmolecular.com/product/sars-cov-2-single-test-total-n1-influenza-a-b/): Wastewater Testing Service targets N1 region of SARS-CoV-2, the virus that causes COVID-19 and Influenza A/B. Includes collection kit and Priority Overnight return shipping. - [Extracted RNA from Wastewater](https://www.gtmolecular.com/product/extracted-rna-from-wastewater/): Extracted RNA from wastewater samples shipped to your lab for archival or testing. We perform the processing in a facility meeting required biosafety levels so you don't have to! - [GT-Digital™ NVO WW Surveillance Assay Kit v1.0 for the QX200®/QX600®-BETA](https://www.gtmolecular.com/product/gt-digital-nvo-ww-surveillance-assay-kit-v1-0-for-the-qx200-qx600-beta/): (Cat# 100825) The GT-Digital™ NVO Wastewater Surveillance Assay Kit v1.0 for the Bio-Rad QX200®/ QX600® Droplet Digital? PCR Systems comprises a molecular reagent kit containing all primers, probes, and controls for the detection of non-variola Orthopoxviruses (NVO), in wastewater. Through use of this kit in conjunction with the Bio-Rad QX200®/ QX600® Droplet Digital® PCR Systems, users can monitor NVO levels in wastewater. Contains enough material for 200 reactions. - [dPCR PMMoV;CrAssphage Assay Kit - Bio-Rad QX200® v1.1 - BETA](https://www.gtmolecular.com/product/dpcr-pmmovcrassphage-assay-kit-bio-rad-qx200-v1-1-beta/): (Cat# 100608-1.1) The dPCR PMMoV;crAssphage Assay Kit for the Bio-Rad QX200® Droplet Digital® PCR System v1.1 comprises a molecular reagent kit containing all primers, probes, and controls for the detection of pepper mild mottle virus (PMMoV) and crAssphage fecal indicators in wastewater. Through use of this kit in conjunction with the Bio-Rad QX200® Droplet Digital® PCR system, users can monitor PMMoV and crAssphage levels in wastewater. Contains enough material for 200 samples. - [Custom Assay Development](https://www.gtmolecular.com/product/custom-assay-development-2/): GT Molecular provides innovative, patent-pending, kitted solutions and streamlined operations for pathogen detection and oncology research applications. Leverage our deep experience spanning in silico oligonucleotide design, multiplexing optimization, working with low concentration analytes, and the nuances associated with difficult sample matrices. Let us help you build the exact assay you need for your research! - [Translational and Foundational Research](https://www.gtmolecular.com/product/custom-assay-development/): Leverage our validated research tools and testing expertise to accelerate preclinical studies and drug discovery. GT Molecular’s patent-pending technology produces market leading assay kits that make it possible to rapidly test for a variety of cancer mutations and pathogens in tough sample matrices and low concentrations. Let us design your assay for mutations, fusions, copy number variations, gene expression, identification, and quantitative detection of novel targets of interest. Contact us today to take your research to the next level! - [Wastewater Surveillance Influenza Subtype/Lineage Discrimination Assay for the Bio-Rad QX200® Platform](https://www.gtmolecular.com/product/ww-surveillance-influenza-subtype-lineage-discrimination-assay-for-the-qx200/): (Cat# 100280) The Wastewater Surveillance Influenza Subtype/Lineage Discrimination Assay Kit v1.0 for the Bio-Rad QX200® contains assay solutions and appropriate controls for the quantification of 1) Influenza A subtypes: 2009 pandemic H1N1 (H1N1pdm09), seasonal H1N1 (H1N1sea), and H3N2; 2) Influenza B sublineages: B-Yamagata (B-Yam) and B-Victoria (B-Vic); and 3) Bovine Coronavirus (BCoV), a matrix recovery control. Through the use of this kit in conjunction with the Bio-Rad QX200?, users can identify and discriminate Influenza subtypes/lineages and normalize for changes in viral recovery caused by the variable and complex nature of wastewater. Contains enough material for 200 reactions. - [dPCR Polio Typing Wastewater Surveillance Assay Kit for the QX200®](https://www.gtmolecular.com/product/dpcr-polio-typing-wastewater-surveillance-assay-kit-for-the-qx200/): (Cat# 100320) The dPCR Polio Typing Wastewater Surveillance Assay Kit for the Bio-Rad QX200® Droplet Digital® PCR System is a molecular reagent kit containing assay solutions and appropriate controls for the quantification and discrimination of 1) Poliovirus types (PV1, PV2 and PV3), 2) Simian virus 6 (SV6), a matrix recovery control (also called an internal process control biologically similar to Poliovirus; and 3) Pepper Mild Mottle virus (PMMoV), a fecal indicator used to quantify human fecal content in a sample. Through use of this kit in conjunction with the Bio-Rad QX200® Droplet Digital® PCR System, users can monitor and type […] - [GT-Digital™ H5* Wastewater Surveillance Assay v1.0 for the Bio-Rad QX200®/QX600® Droplet Digital® PCR System](https://www.gtmolecular.com/product/gt-digital-h5-wastewater-surveillance-assay-v1-0-for-the-bio-rad-qx200-or-qx600-droplet-digital-pcr-system/): (Cat# 100780) The GT-Digital™ H5* Wastewater Surveillance Assay v1.0 for the BioRad QX200® or QX600® Droplet Digital™ PCR System is a molecular reagent kit consisting of all primers, probes, and controls necessary for wastewater surveillance of H5* influenza A subtype. Assay solutions and appropriate controls are provided for the quantification of H5* influenza. Through the use of this kit in conjunction with the Bio-Rad QX200™ or QX600™ Droplet Digital™ PCR System, users can monitor H5* influenza levels. *DISCLAIMER! This assay was designed to ensure detection of H5N1 subtypes from avian, cattle, and human origin. Importantly, this assay is predicted to […] - [GT-Digital™ H5* Wastewater Surveillance Assay v1.0 for the QIAcuity® Digital PCR System](https://www.gtmolecular.com/product/gt-digital-h5-wastewater-surveillance-assay-kit-for-the-qiagen-qiacuity-digital-pcr-system-copy/): (Cat# 100775) The GT-Digital™ H5* Wastewater Surveillance Assay v1.0 for the QIAcuity® Digital PCR System comprises a molecular reagent kit containing all primers, probes, and controls for wastewater surveillance of H5* influenza A subtype. Assay solutions and appropriate controls are provided for the quantification of H5* influenza. Through the use of this kit in conjunction with the QIAGEN QIAcuity® instrument, users can monitor H5* influenza levels. *DISCLAIMER! This assay was designed to ensure detection of H5N1 subtypes from avian, cattle, and human origin. Importantly, this assay is predicted to detect other H5 subtypes of influenza such as H5N6, H5N9, etc. […] - [GT-Digital™ BCR-ABL Fusion Detection Panel v1.0 for the Roche Digital LightCycler™ System](https://www.gtmolecular.com/product/gt-digital-bcr-abl-fusion-detection-panel-v1-0-for-the-roche-digital-lightcyclertm-system/): (Cat# 100815) A Research-Use Only (RUO), patent-pending kit provides all the necessary primers, probes, and controls to detect and quantify human RNA with the following BCR-ABL translocations: major (e13a2, e13a3, e14a2, e14a3), minor (e1a2, e1a3), micro (e19a2, e19a3), and nano (e6a2, e6a3). This multi-target kit contains one assay solution, an ABL1 positive control, and positive controls for each fusion type (e14a2, e1a2, e19a2, and e6a2). Contains enough material for 50 reactions. - [GT-Digital™ ESR1 Mutation Panel v1.0 for the Roche Digital LightCycler™ System](https://www.gtmolecular.com/product/gt-digital-esr1-mutation-panel-v1-0-for-the-roche-digital-lightcyclertm-system/): (Cat# 100805) A Research-Use Only (RUO) and patent-pending molecular reagent kit comes fully equipped with all the necessary primers, probes, and controls to detect and quantify common mutations in the human ESR1 gene linked to breast cancer. Our comprehensive multi-target kit includes one assay solution and two qualitative controls, specifically designed to target the following ESR1 mutations: E380Q, S463P, L536H/R/P, Y537C/S/N, and D538G. To ensure precision and reliability, the kit also provides a wild-type ESR1 control and a 10% mutant control. Contains enough material for 50 reactions. - [GT-Digital™ Wastewater Surveillance Norovirus GI;GII;BCoV Panel v1.0 for the Roche Digital LightCycler™ System](https://www.gtmolecular.com/product/gt-digital-wastewater-surveillance-norovirus-gigiibcov-panel-v1-0-for-the-roche-digital-lightcyclertm-system/): (Cat# 100795) A multiplexed digital PCR assay kit for the detection and quantification of 1) norovirus GI; 2) norovirus GII; and 3) Bovine Coronavirus (BCoV), a matrix recovery control (also called a process control). Through the use of this kit in conjunction with the Roche Digital LightCycler™ instrument, users can monitor norovirus GI;GII levels and normalize for changes in viral recovery caused by the variable and complex nature of wastewater. Contains enough material for 200 reactions. - [GT-Digital™ Wastewater Surveillance C. auris;C. cayetanensis;Campylobacter spp. Panel for the Roche Digital LightCycler™ System](https://www.gtmolecular.com/product/gt-digital-wastewater-surveillance-c-aurisc-cayetanensiscampylobacter-spp-panel-for-the-roche-digital-lightcyclertm-system/): (Cat# 100760) A multiplexed digital PCR assay kit for the detection and quantification of Candida auris (C. auris), Cyclospora cayetanensis (C. cayetanensis), and Campylobacter spp. Through the use of this kit in conjunction with the Roche Digital LightCycler™ instrument, users can monitor the above microorganisms in wastewater. Contains enough material for 200 reactions. - [GT-Digital™ Wastewater Surveillance mcr-1;intl1;tetW;vanA Panel for the Roche Digital LightCycler™ System](https://www.gtmolecular.com/product/gt-digital-wastewater-surveillance-mcr-1intl1tetwvana-panel-for-the-roche-digital-lightcyclertm-system/): (Cat# 100790) A multiplexed digital PCR assay kit for the detection and quantification of mobile colistin resistance 1 (mcr-1), integron-integrase 1 (intl1), tetracycline resistance (tetW), and vancomycin resistance (vanA) gene targets in bacterial organisms. Through the use of this kit in conjunction with the Roche Digital LightCycler™ instrument, users can monitor the above antimicrobial resistance genes in wastewater. Contains enough material for 200 reactions. - [GT-Digital™ Wastewater Surveillance Carbapenem-AMR Panel for the Roche Digital LightCycler™ System](https://www.gtmolecular.com/product/gt-digital-wastewater-surveillance-carbapenem-amr-panel-for-the-roche-digital-lightcyclertm-system/): (Cat# 100695) A multiplexed digital PCR assay kit for the detection and quantification of Oxacillinase-48 (OXA-48), verona integron-encoded metallo-beta-lactamase (VIM), Klebsiella pneumoniae carbapenemase (KPC), New Delhi metallo-beta-lactamase (NDM), and imipenemase (IMP) carbapenem antimicrobial resistance (AMR) gene targets in bacterial organisms. Through the use of this kit in conjunction with the Roche Digital LightCycler™ instrument, users can monitor the above carbapenem resistance genes in wastewater. Contains enough material for 200 reactions. - [GT-Digital™ KRAS G12C;G12 Assay Kit v1.0 for the QIAGEN QIAcuity™](https://www.gtmolecular.com/product/gt-digitalr-kras-g12cg12-assay-kit-v1-0-for-the-qiagen-qiacuitytm/): (Cat# 100680) The GT-Digital™ KRAS G12C;G12 Assay Kit for the QIAcuity™ Digital PCR System is a Research-Use Only (RUO) molecular reagent kit containing all primers, probes, and controls for the detection and quantification of the G12C mutation found in the human KRAS gene. This duplexed assay comprises a FAM probe that targets the mutated G12C sequence and a HEX probe that targets the nonmutated G12 sequence. Contains enough material for 50 reactions. - [GT-Digital™ IDH1/IDH2/NPM1 Mutation Panel v1.0 for the Roche Digital LightCycler™ System](https://www.gtmolecular.com/product/gt-digitalr-idh1-idh2-npm1-mutation-panel-v1-0-for-the-roche-digital-lightcyclertm-system/): (Cat# 100730) The GT-Digital™ IDH1/IDH2/NPM1 Mutation Panel for the Roche Digital LightCycler™ System is a Research-Use Only (RUO), patent-pending molecular reagent kit containing all primers, probes, and controls for the detection and relative abundance of common mutations found in the human IDH1, IDH2, and NPM1 genes. This multi-target kit contains one assay solution and three qualitative controls. Contains enough material for 50 reactions. [comment]: # (Generated by Hostinger Tools Plugin)